Omron MX2 Series User Manual page 62

Multi-function compact inverter
Hide thumbs Also See for MX2 Series:
Table of Contents

Advertisement

1 Overview
Parameter
No.
C004
Multi-function Input 4 Selec- tion
C042
Arrival Frequency During Accel-
eration 1
C043
Arrival Frequency During Decel-
eration 1
C045
Arrival Frequency During Accel-
eration 2
C046
Arrival Frequency During Decel-
eration 2
P071
Origin Search Mode 2 Fre-
quency
*1. In high-frequency mode.
Data can be changed during RUN
From Soft Lock Selection (b031) of the 3G3MX2-E Series Inverter, 10 (Data can be changed during
RUN) selection is deleted, and Data can be changed during RUN is always enabled.
To prevent unintended changes to parameters, use the Soft Lock Selection (b031). (Refer to 7-6-1 Soft
Lock Function (SFT) on page 7-54). To prevent unintended changes, use the password function (refer
to 7-6-9 Password Function on page 7-57).
However, it is not possible to write-protect only a portion of the parameters.
The 3G3MX2-EV2 Series Inverter allows you to change the following parameters during RUN, although
the 3G3MX2-E Series Inverter does not allow it. For parameters for which you can change data during
RUN, refer to the lists in Section 4 Parameter List.
Parameter No.
F004
A081/A282
A095/A295
A096/A296
b051
b052
b053
b054
b093
C096
H117
H118
P039
P040
P081
P082
P083
P200
P201 to P210
1 - 30
Function name
00 to 09, 11 to 16, 18 to 24, 27
to 29, 31 to 42, 44, 46, 47, 50
to 53, 56 to 62, 65 to 70, 73,
78, 81 to 86, 91
255: no
0.00 to 400.00 (580.00)
0.00 to 400.00 (580.00)
0.00 to 400.00 (580.00)
0.00 to 400.00 (580.00)
0.00 to 400.00 (580.00)
Function name
RUN Direction Selection
AVR Selection
2-step Acceleration Frequency
2-step Deceleration Frequency
Starting Voltage on Power Interruption
Deceleration Hold Level on Power Interruption
Deceleration Time on Power Interruption
Deceleration Starting Width on Power Interruption
Total Fan Operation Time Clear
Communication Selection
PM Motor Starting Current
PM Motor Starting Time
Speed Limit Value in Torque Control (Forward)
Speed Limit Value in Torque Control (Reverse)
Position Store Selection at Power Off
Position Data at Power Off
Preset Position Data
Modbus Mapping Function Selection
Modbus Mapping
External Register 1 to 10
Multi-function Compact Inverter 3G3MX2-EV2 User's Manual (I666-E1)
Data range
3G3MX2-E
00 to 09, 11 to 16, 18, 20 to 24,
27 to 29, 31 to 42, 44, 46, 47,
50 to 53, 56 to 62, 65 to 70,
73, 81 to 86, 91
255: no
*1
0.00 to 590.00
0.00 to 590.00
*1
0.00 to 590.00
*1
0.00 to 590.00
*1
0.00 to 590.00
*1
3G3MX2-EV2