Window Comparator (Wco/Wcoi) (Disconnection Detection Odc/Oidc) - Omron MX2 Series User Manual

Multi-function compact inverter
Hide thumbs Also See for MX2 Series:
Table of Contents

Advertisement

7-8-20 Window Comparator (WCO/WCFI) (Disconnection Detection
ODc/FIDc)
The window comparator signal will be output when the analog input O/OI value is between the upper
and lower limit settings. It is useful for monitoring the analog input at a level to detect disconnection or
other faults.
The hysteresis width can be set for the upper and lower limit level settings for the window comparator
function.
In addition to the hysteresis width, the upper and lower limit levels can be set individually for each of the
analog input signals O and OI.
The analog operation level during WCO/WCOI output can be set to a fixed value. To do so, set the
Analog Operation Level at O/OI/FE Disconnection (b070/b071). When set to no, the analog input value
will be used "as is."
The signals ODc and OIDc will be output in the same way as WCO and WCOI, respectively.
Parameter
No.
Window Comparator O
b060
Upper Limit Level
Window Comparator OI Upper
b063
Limit Level
Window Comparator O
b061
Lower Limit Level
Window Comparator OI Lower
b064
Limit Level
Window Comparator O Hys-
b062
teresis Width
Window Comparator OI Hys-
b065
teresis Width
Analog Operation Level at O
b070
Disconnection
Analog Operation Level at OI
b071
Disconnection
Multi-function Output 11/12
C021
Selection
C022
Multi-function Relay Output
C026
(AL1, AL2) Function Selection
Note Set the upper and lower limit level settings for the window comparator function as a percentage [%] of the
input voltage (10 V) or current (20 mA).
Multi-function Compact Inverter 3G3MX2-EV2 User's Manual (I666-E1)
Function name
Lower limit level + Hysteresis width  2
(0. min.) to 100.
Set an upper limit level.
0. to Lower limit level − Hysteresis width 
2 (100. max.)
Set a lower limit level.
0. to (Upper limit level − Lower limit level)
 2 (10. max.)
Set a hysteresis width for the upper and
lower limit levels.
0. to 100.
255: no (Disabled)
Set the analog operation level during
WCO/WCOI (ODc/OIDc) output.
27:
28:
54:
55:
Data range
ODc (Analog O disconnection
detection)
OIDc (Analog OI
disconnection detection)
WCO
(Window Comparator O)
WCOI
(Window Comparator OI)
7 Other Functions
Default
Unit
data
100.
%
0.
%
0.
%
no
%
7 - 91