Para-
Function
meter
name
No.
0.20  Heavy load rated
Digital Current
current to 2.00 
Monitor Refer-
C030
ence Value
Heavy load rated current [A]
0.00 to 2.00  Heavy load
Low Current
C039
Detection Level
rated current [A]
0.00:
1st Overload
C041
Warning Level
0.01 to 2.00  Heavy load
2nd Overload
C241
rated current [A]
Warning Level
0.00:
1st Overload
Warning Level 2
C111
0.01 to 2.00  Heavy load
rated current [A]
1st Motor
0.1 to 18.5 [kW]
H003
Capacity
Setting in steps
2nd Motor
Capacity
H203
*1. Conversion: The set current value will be converted at the ratio of the rated current for the heavy load/light load mode.
(Example) If you change from a light load mode setting of 5 A (rated current: 10 A) to the heavy load mode (rated current:
8 A), the current value will be converted as follows: Rated current 8 A × 50% (5 A/10 A) = 4 A.
*2. Setting in steps: Steps of 0.1/0.2/0.4/0.55/0.75/1.1/1.5/2.2/3.0/3.7/4.0/5.5/7.5/11.0/15.0/18.5 [kW] can be selected.
In the light load mode, the following parameters are not displayed.
Parameter No.
d009
d010
d012
b040
b041
b042
b043
b044
b045
b046
C054
C055
C056
Multi-function Compact Inverter 3G3MX2-EV2 User's Manual (I666-E1)
Setting range
Heavy load (CT)
0.20  Light load rated
current to 2.00  Light load
rated current [A]
0.00 to 2.00  Light load
rated current [A]
Overload warning
0.00:
detection disabled
0.01 to 2.00  Light load
rated current [A]
Overload warning
0.00:
detection disabled
0.01 to 2.00  Light load
rated current [A]
Same as the setting range for
heavy load mode
*2
Function name
Torque Reference Monitor
Torque Bias Monitor
Output Torque Monitor
Torque Limit Selection
Torque Limit 1
(Four-quadrant Mode Forward
Power Running)
Torque Limit 2
(Four-quadrant Mode Reverse
Regeneration)
Torque Limit 3
(Four-quadrant Mode Reverse
Power Running)
Torque Limit 4
(Four-quadrant Mode Forward
Regeneration)
Torque LADSTOP Selection
Reverse Rotation Prevention Selec-
tion
Overtorque/Undertorque Selection
Overtorque/Undertorque Level
(Forward Power Running)
Overtorque/Undertorque Level
(Reverse Regeneration)
Default data
Heavy
Light load (VT)
load (CT)
Normal-
load rated
current [A]
Normal-
load rated
current [A]
1.15 
Overload warning
detection disabled
Normal-
load rated
current [A]
1.15 
Overload warning
detection disabled
Normal-
load rated
current [A]
Max.
applicable
motor
capacity for
heavy load
[kW]
Parameter No.
H005/H205
1st/2nd Speed Response
H020/H220
1st/2nd Motor Parameter R1
H021/H221
1st/2nd Motor Parameter R2
H022/H222
1st/2nd Motor Parameter L
H023/H223
1st/2nd Motor Parameter Io
H024/H224
1st/2nd Motor Parameter J
1st/2nd Motor Parameter R1
H030/H230
(Auto-tuning Data)
1st/2nd Motor Parameter R2
H031/H231
(Auto-tuning Data)
1st/2nd Motor Parameter L
H032/H232
(Auto-tuning Data)
1st/2nd Motor Parameter Io
H033/H233
(Auto-tuning Data)
1st/2nd Motor Parameter J
H034/H234
(Auto-tuning Data)
P033
Torque Reference Input Selection
P034
Torque Reference Setting
5 Basic Settings
Initialization at
load mode
switching
Light
Normal
Light to
load (VT)
to Light
Normal
Light load
*1
Conversion
Conversion
rated
current [A]
Light load
*1
Conversion
Conversion
rated
current [A]
1.15 
*1
Conversion
Conversion
Light load
rated
current [A]
1.15 
*1
Conversion
Conversion
Light load
rated
current [A]
Max.
Disabled
Disabled
applicable
motor
capacity for
light load
[kW]
Function name
5 - 13
*1
*1
*1
*1
5