Group P: Option/Applied Function Parameters - Omron MX2 Series User Manual

Multi-function compact inverter
Hide thumbs Also See for MX2 Series:
Table of Contents

Advertisement

4-3-5

Group P: Option/Applied Function Parameters

Parameter
Function name
No.
Operation Selection on
P001
Option Error
Pulse Train Input EA
P003
Selection
Pulse Train Input Type
P004
Selection
Number of Encoder
P011
Pulses
Simple Position Con-
P012
trol Selection
Creep Speed Moving
P014
Amount
P015
Creep Speed Setting
Positioning Completion
P017
*1
Range Setting
Overspeed Error
P026
Detection Level
Speed Deviation
P027
Excessive Level
Acceleration/Decel-
eration Time Input
P031
Type
Torque Reference
P033
Input Selection
Torque Reference
P034
Setting
P036
Torque Bias Selection
P037
Torque Bias Value
Torque Bias Polarity
P038
Selection
Speed Limit Value in
P039
Torque Control (For-
ward)
Speed Limit Value in
P040
Torque Control
(Reverse)
Speed/Torque
P041
Switching Time
*1. In high-frequency mode.
Multi-function Compact Inverter 3G3MX2-EV2 User's Manual (I666-E1)
Monitor or data range
00: Trip
01: Continue operation
00: Frequency setting (including PID)
01: Feedback pulse (enabled only
when 1st control is selected)
02: MI8 (General-purpose input 8 for
DriveProgramming)
00: Single-phase pulse train
01: Phase A and B 90°phase difference
pulse train
02: Do not set.
03: Single-phase pulse train + direction
32. to 1024.
00: Simple position control disabled
02: Simple position control enabled
0.0 to 400.0
Starting Frequency to 10.00 (100.00)
0. to 10000. (×4 multiplication)
0.0 to 150.0
0.00 to 120.00
00: Digital Operator
03: DriveProgramming
00: Terminal O
01: Terminal OI
03: Digital Operator
06: Option (No applicable Option)
0. to 200.
00: Disabled
01: Digital Operator
05: Option (No applicable Option)
−200. to 200.
00: As per sign
01: Dependent on RUN direction
0.00 to 120.00
0.00 to 120.00
0. to 1000.
4 Parameter List
Changes
Default
Set
during
data
data
RUN
00
Enabled
00
Disabled
00
Disabled
512.
Disabled
00
Disabled
125.0
Disabled
*1
5.00
Enabled
50.
Disabled
115.0
Enabled
10.00
Enabled
00
Disabled
00
Disabled
0.
Enabled
00
Disabled
0.
Enabled
00
Disabled
0.00
Enabled
0.00
Enabled
0.
Disabled
Unit
Page
P. 7-105
P. 6-18
P. 7-52
P. 6-18
P. 6-28
pulse
4
P. 6-34
%
P. 6-50
Hz
pulse
P. 6-45
%
P. 6-23
Hz
P. 5-32
P. 6-16
%
P. 6-17
%
Hz
P. 6-16
Hz
ms
4 - 35