AMU-II Oxytrace
Default Values
Relay 1
Relay 2
Input:
A-96.150.541 / 111223
Case temp. high:........................................................................ 65 °C
Case temp. low: ........................................................................... 0 °C
Function: .............................................................................limit upper
Parameter: ..............................................................................Oxygen
Setpoint:............................................................................. 10.00 ppm
Hysteresis: ............................................................................. 100 ppb
Delay:........................................................................................... 30 s
Function: .............................................................................limit upper
Parameter: ...................................................................... Temperature
Setpoint:.................................................................................. 50.0 °C
Hysteresis: ................................................................................ 1.0 °C
Delay:........................................................................................... 30 s
If Function = Control upw. or dnw:
Parameter: ..............................................................................Oxygen
Settings: Actuator: ............................................................. Frequency
Settings: Pulse Frequency: ................................................120/min
Settings: Control Parameters: Setpoint: ......................... 10.00 ppm
Settings: Control Parameters: P-band:............................ 100.0 ppb
Settings: Control Parameters: Reset time: ................................. 0 s
Settings: Control Parameters: Derivative Time: ......................... 0 s
Settings: Control Parameters: Control Timeout:..................... 0 min
Settings: Act. Time prop.: Cycle time: ...................................... 60 s
Settings: Act. Time prop.: Response time: .............................. 10 s
Settings: Act. Motor valve: Run time: ...................................... 60 s
Settings: Act. Motor valve: Neutral zone: .................................. 5%
If Function = Timer:
Mode:...................................................................................... Interval
Interval:................................................................................... 1 min
Mode: ..........................................................................................daily
Start time: .......................................................................... 00.00.00
Mode:....................................................................................... weekly
Calendar; Start time: ......................................................... 00.00.00
Calendar; Monday to Sunday:.................................................... Off
Run time: ..................................................................................... 10 s
Delay:............................................................................................. 5 s
Signal output:............................................................................... cont
Output/Control: ............................................................................ cont
Active .............................................................................. when closed
Signal Outputs ............................................................................. hold
Output/Control ................................................................................ off
Fault................................................................................................ no
Delay............................................................................................ 10 s