Branson 2000 Series Installation Manual page 55

Hide thumbs Also See for 2000 Series:
Table of Contents

Advertisement

2000 Series
Installation Guide
Table 16
Converter Duty Cycle and Cooling
Max Power
100% at 2000 W
4000 W
50% at 3300 W
25% at 4000 W
100% at 800 W
1500 W
50% at 1500 W
80% at 300 W
800 W
40% at 700 W
100% at 600 W
100% at 400 W
800 W
1. Maximum time for sonics on at the% of Duty Cycle.
2. Conditions at which data points were recorded
100-214-226 Rev. 10
% Duty Cycle
40 kHz 4TP Solid Mount Converter
40 kHz 4TR, 4TH and 4TJ Converters
75% at 700 W
50% at 800 W
70% at 600 W
40% at 800 W
60% at 400 W
20% at 700 W
Assemble the Acoustic Stack
1
Duty Cycle
20 kHz
10 seconds
30 kHz
2 seconds
1 second
1 second
1 second
1 second
Ambient Conditions
Cooling air of 30 C @ 80cfh
Cooling air of 30 C @ 80scfh
at 50 C ambient
No cooling air, 40 C ambient
Cooling air of 30 C @ 50scfh
Cooling air of 30 C @ 25scfh
No cooling air
2
49

Advertisement