Electrical Input Power Ratings

Plug the Power Supply into a single-phase, grounded, 3-wire, 50 or 60 Hz power source. Table 5
lists the current, fuse ratings and Plugs for the various models.
Table 5
Input Power and Plug Requirements
For 15 kHz models
3300 W 200V - 240V
1100 W 200V - 240V
1100 W 100V - 120V
For 20 kHz models
2200 W 200V - 240V
3300 W 200V - 240V
4000 W 220V - 240V
1500 W 100V - 120V*
For 30 kHz models
1500 W 200V - 240V
400 W 200V - 240V
400 W 100V - 120V
For 40 kHz models
800 W 200V - 240V
800 W 100V - 120V
For 60 kHz model
200 W 100V - 120 V
* requires a specific 20 amp 120V receptacle
The voltages shown in the above table have the following operational tolerances:
100V - 120V nominal, 90 - 132 operational
200V - 240V nominal, 180 - 253 operational
10
19 Amp Max. @ 200V / 20 Amp fuse
7 Amp Max. @ 200V / 20 Amp fuse
13 Amp Max. @ 100V / 20 Amp fuse
13 Amp Max. @ 200V / 20 Amp fuse
19 Amp Max. @ 200V / 20 Amp fuse
21 Amp Max. @ 220V / 25 Amp fuse
20 Amp Max. @ 100V / 20 Amp fuse
10 Amp Max. @ 200V / 20 Amp fuse
3 Amp Max. @ 200V / 20 Amp fuse
5 Amp Max. @ 100V / 20 Amp fuse
5 Amp Max. @ 200V / 20 Amp fuse
10 Amp Max. @ 100V / 20 Amp fuse
3 Amp Max. @ 100V / 3 Amp fuse
NEMA L6-20P Plug
NEMA L6-20P Plug
NEMA 5-15P Plug
NEMA L6-20P Plug
NEMA L6-20P Plug
NEMA L6-20P Plug
NEMA 5-20P Plug
NEMA L6-20P Plug
NEMA L6-20P Plug
NEMA 5-15P Plug
NEMA L6-20P Plug
NEMA 5-15P Plug
NEMA 5-15P Plug