2000 Series
Installation Guide
Installation Requirements
Location
The actuator or stand may be installed in a variety of positions. The stand (mounted on a base) is
often manually operated, using its base-mounted start switches, and so is installed at a safe (being
able to support at least 250 pounds) and comfortable workbench height (approximately 30-36
inches for seated operation, 36-42 for standing) with the operator sitting or standing in front of the
system. Stands (on hubs) are designed for use in automated systems and may be manually or
automatically loaded and unloaded.
WARNING
Stand may tip over if rotated around the axis of its column. Secure base or hub.
i
NOTE
i
The work surface on which a stand is installed must be sturdy enough to support it, and
secure enough to not tip over when the stand is adjusted during installation or setup.
The power supply may be located up to 25 feet away for the 15kHz, (50' for 20kHz, 20' for 30kHz,
and 15' for 40kHz models) from the actuator. The power supply must be accessible for user
parameter changes and settings, and must be placed in a horizontal orientation for purposes of
heat management. The power supply should be positioned so it does not draw in dust, dirt or
material via its rear fans. See Figure 5 for a dimensional drawing. All dimensions are approximate
and may vary between models.
Environmental Specifications
Table 4
Environmental Specifications
Environmental Concern
Humidity
Ambient Operating Temperature
Storage / Shipping Temperature
100-214-226 Rev. 10
Installation Requirements
Acceptable Range
30% to 95%, non-condensing
+5°C to +50°C (41°F to 122°F)
-25°C to +55°C (-13°F to +131°F);
Up to +70°C (+158°F) for 24 hours
9