Mounting The Fixture On The Branson Base - Branson 2000 Series Installation Manual

Hide thumbs Also See for 2000 Series:
Table of Contents

Advertisement

2000 Series
Installation Guide

Mounting the Fixture on the Branson Base

(hardware and mounting holes)
The base provides mounting holes for your fixture. Mounting holes are also provided for the
optional Branson leveling plate kit. The base is tapped for metric M10-1.5 hardware (indicated by
an "M" on the base). The mounting holes are arranged in three concentric bolt circles with the fol-
lowing dimensions.
CAUTION
The base is cast metal and the mounting holes can become stripped if the hardware is over-
tightened. Tighten your hardware only enough to prevent movement of your fixture.
Figure 30 Mounting Circles on Base
M = metric M10 hardware
12.50 inch
317.5 mm
Leveling Plate
mounting dimensions
The optional guard, EDP 101-063-550, (sometimes required with very large horns) is shown for
position only. It extends several inches to either side of the base, and prevents the user from oper-
ating the welder and pinching their fingers or hands between the base and the tooling.
100-214-226 Rev. 10
9.00 in / 229mm
7.00 in / 178 mm
4.44 in / 113 mm
10.50 in
287 mm
Assemble the Acoustic Stack
Optional
Guard
shown for
position only
47