User I/O Dip Switch (Sw1) - Branson 2000 Series Installation Manual

Hide thumbs Also See for 2000 Series:
Table of Contents

Advertisement

2000 Series
Installation Guide

User I/O DIP Switch (SW1)

DIP switch SW1, for the user I/O is located next to the J3 on the back of the 2000-series power supply, as
shown in
Figure 20 on page
setting is for all dip switches is set to ON (
• If the dip switch is set to the ON (closed) position, the corresponding Output pin will be configured as the
current source, 25mA max.
• If the dip switch is set to the OFF (open) position, the corresponding Output pin will be configured as an
"open collector", 24VDC, 25 mA max. current sink.
Table 12
User I/O DIP Switch Functions
Switch Position
1
REJECT_SIG
2
SUSPECT_SIG
3
PB_RELEASE_SIG
4
G_ALARM_SIG
5
READY_SIG
6
WELD_ON_SIG
7
ACTUATOR_CLEAR_SIG
8
J3_22_OUT_SIG
9
J3_36_OUT_SIG
10
J3_8_OUT_SIG
i
i
NOTE
Do not permanently remove the Cover from the Power Supply because it is required for
proper system cooling.
100-214-226 Rev. 10
-27. The settings of these switches affect the user I/O signals. Factory default
closed:
Signal Description
Start Switch Connection (Automation)
switch position closest to number designation).
Output Signal
REJECT
SUSPECT
PB_RELEASE
G_ALARM
READY
WELD_ON
ACT_CLEAR
J3_22_OUTPUT
J3_36_OUTPUT
J3_8_OUTPUT