Installation Guide
Figure 18 Mounting bolt pattern for the Hub (for Stand on Hub)
3/8 inch or
M10 bolts
(4 places)
2.22 in /
56 mm
Column
Bolts
1.
Locate the hub in the desired location. Ensure no overhead or side obstructions will interfere with
normal operation or use of the system.
i
NOTE
i
Mount the hub to your work surface using four bolts, 3/8-inch or M10 shank size, with flat
washers against its metal casting (customer provided hardware).
2.
Carefully lift the actuator and column assembly, and mount the column in the hub. Align the flat face
of the spring swivel with the top-front of the actuator. Tighten the two bolts on the hub.
3.
Connect factory air to the air hose on the stand (3/8 NPT male fitting on the hose). A quick-
disconnect fitting is suggested. Use a lockout device on the air line if required.
4.
Verify the base/start switch control cable is properly connected to the back of actuator.
5.
Verify the linear encoder connector is properly connected to the back of the actuator.
6.
Use jack screws to fine adjust the system level. A 3/16" allen wrench should be used for the 3/8"-
16 x 3/4" jack screws.

Actuator (alone)

The actuator (alone) is intended for installation on your custom-made mounting support. It is
located in place with a mounting pin and secured using three metric bolts.
1.
Lift the actuator from the box. Carefully lay the assembly on its right side (NOT on the side with the
linear encoder).
100-214-226 Rev. 10
10.50 in / 267 mm
3.94 in / 100mm
0.94 in / 24 mm
(four places)
Rear of Hub
6.00 in / 152 mm
5.25 in / 133 mm
Jack Screws(4)
Front of Hub
Factory Air
Front of Hub
0.59 in /
11 mm
4.44 in /
113 mm
3.25 in /
83 mm
25