Branson 2000 Series Installation Manual page 39

Hide thumbs Also See for 2000 Series:
Table of Contents

Advertisement

2000 Series
Installation Guide
8
J3_8_OUTPUT
22
J3_22_OUTPUT
36
J3_36_OUTPUT
9
MEM
11
MEM_CLEAR
40
MEMORY_STORE
34
PB_RELEASE
37
PWR
21
READY
5
REJECT
43
READY_ RELAY_1
15
READY_RELAY_2
26
RUN
39
SEEK
4
SOL_VALVE_SRC
16
SOL_VALVE_RTN
20
SUSPECT_PART
10
USER_AMP_IN
25
USER_FREQ_OFFSET
35
WELD_ON
30
WELD_ON_RELAY_1
44
WELD_ON_RELAY_2
CAUTION
Ensure all unused wires are properly isolated. failure to do so may result in Power Supply or
system failure.
Pin
Signal Name
23
+10V_REF
12
24V_RTN
13
24V_SRC
27
24V_RTN
28
24V_SRC
41
24V_RTN
42
24V_SRC
You can find additional information about
power supply or actuator manual, version 9.x software only.
100-214-226 Rev. 10
24V True
Output
24V True
Output
24V True
Output
Analog
Output
Open Collector
Output
Open Collector
Output
0V True
Output
Analog
Output
0V True
Output
0V True
Output
Relay Contact
Output
Relay Contact
Output
Open Collector
Output
Open Collector
Output
24V
Output
24V Return
Input
0V True
Output
Analog
Input
Analog
Input
0V True
Output
Relay Contact
Output
Relay Contact
Output
Signal Type
Direction
Analog
Output
24V Ground
Input
24V Source
Output
24V Ground
Input
24V Source
Output
24V Ground
Input
24V Source
Output
User I/O Input and Output Function Selection in your
Start Switch Connection (Automation)
0/24V, 100mA
User definable outputs. Refer to
Table 4.7 to view available
0/24V, 100mA
selections.
0/24V, 100mA
-10V to +10V
Memory Signal from PS
24V, 25mA max
Memory Clear signal send to PS
24V, 25mA max
Memory store from PS
0/24V, 100mA
0V to 10V
Power Signal from PS
0/24V, 100mA
0/24V, 100mA
40V, 0.25A
Contact Closure
40V, 0.25A
Contact Closure
24V, 25mA max
Run signal send to PS
24V, 25mA max
Seek Signal send to PS
0/24V, 125mA
SV1 Source
0V
SV1 Return
0/24V, 100mA
-10V to +10V
User Amplitude control signal
-10V to +10V
User Freq. offset control signal
0/24V, 100mA
Start of sonics and trigger
40V, 0.25A
Contact Closure
40V, 0.25A
Contact Closure
Signal Range
Definition
10.0V
10VDC ref. voltage from PS
0V
24V Return
24V, 1.25A max
24V Source
0V
24V Return
24V, 1.25A max
24V Source
0V
24V Return
24V, 1.25A max
24V Source
Grn/Wht
Blk/Red/Grn
Orn/Red Grn
Blu/Wht
Wht/Red
Red/Wht/Blu
Red/Wht/Grn
Blu/Red/Grn
Blu/Blk/Wht
Blu/Blk
Blu/Orn/Red
Orn/Grn
Orn/Blk/Grn
Wht/Blk/Blu
Orn/Blk
Blk/Wht/Red
Orn/Blk/Wht
Blk/Red
Grn/Blk/Orn
Grn/Wht/Blu
Orn/Wht/Blu
Blk/Orn/Red
Colors
Wht/Red/Grn
Orn/Red
Blu/Red
Blu/Wht/Orn
Blk/Wht/Orn
Grn/Orn/Red
Orn/Red/Blu
33

Advertisement

Table of Contents
loading

Table of Contents