3. Setup Screen
Screen image
(1)
(2)
(3)
Display items
Display item
(1) Manual measurement
status display
(2) Counter display
L meas : Z (Axis name)
R meas : X (Axis name)
(3) Reference surface height
This displays the manual measurement status.
Refer to the " Manual measurement status display " section for further details.
TLM value : This displays the value during measurement.
This will be the same as the machine position until the sensor is contacted.
This will be the skip coordinate position after the sensor is contacted.
Measurement value :
For tool length measurement type I : TLM value − Reference surface height
For tool length measurement type II : TLM value − Reference surface height +
For tool radius measurement, measurement result is displayed in absolute value.
(Note) The TLM value counter differs according to the parameter "#1328 TLM type"
value.
0 : The position when the measurement switch was turned ON is displayed
as 0.
1 : The display is based on the machine zero point.
The axis selected in the parameters "#8711 TLM L meas axis" and "#8712 TLM D
meas axis" is the target axis for the measurement.
This displays a value for the reference surface height.
The setting range is from -99999.999 to 99999.999(mm)
95
3.3 Tool Measurement
(4)
Details
TLM reference length
(5)