3. Setup Screen
<Group 4 display mode> (#1107 Tllfsc = 2)
Display items (L system)
<Group information>
Display item
(1) Group
(2) Form
(3) Life
<Life management data within group>
Display item
(4) #
(5) Tool No.
(6) Comp No.
(7) Used
(8) ST
Life management group No.
This displays whether to control the currently displayed group
in usage hours or usage count.
This sets the tool life data for the currently displayed group.
The following tool life data units display based on the control
method.
Usage time : (s)
Usage count : (set)
This displays whether the tool for which the # No. is highlighted
is a life tool (ST=2) or a skip tool (ST=3).
This sets the tool No.
This sets the compensation No.
This sets the usage data at such times as when the tool is not
an unused tool.
This becomes " 0 " when the usage data is not set.
The following usage data units display based on the control
method.
Usage time : (s)
Usage count : (set)
This sets the tool status.
This becomes " 0 " when the tool status is not set.
0: Unused tool
1: Used tool
2: Normal life tool
3: Skipped tool
120
3.5 Tool Life Management
Details
Details
Setting range
1 to 9999
0 : Hours
1 : Times
Usage time:
0 to 99999999 (s)
Usage count:
0 to 999999 (set)
Setting range
1 to 999999
1 to 80
Usage time:
0 to 99999999 (s)
Usage count:
0 to 999999 (set)
Setting can be
omitted.
0 to 3
Setting can be
omitted.