Recalling Configurations From The User Presets; Storing Configurations From The User Presets; Disabling Preset Recall When The Video Input/Output Standards Change; Recall Presets Via Gpis - evertz 7700 Manual

Hd key/fill up converter
Hide thumbs Also See for 7700:
Table of Contents

Advertisement

6.6.1.1.

Recalling Configurations from the User Presets

Utilities
Recall Preset
Cancel
Factory
1 to 10
6.6.1.2.

Storing Configurations from the User Presets

Utilities
Store Preset
Cancel
1 to 10

6.6.2. Disabling Preset Recall when the Video Input/Output Standards Change

Utilities
Auto Preset Recall
Enable
Disable

6.6.3. Recall presets via GPIs

The converter modules provide ten user preset areas which can be recalled via external GPI inputs. There
are four controls that are used to set functions of the GPI inputs. For simplicity, only one control will be
shown in the manual.
Utilities
GPIO 1
OFF
1-10

6.6.4. Displaying the Status Window on the OSD Output

Utilities
Status Window
Disable
Enable
This control is used to initiate a recall of the current card configuration from
one of the user presets.
Use the toggle switch to select the preset location where you want to recall
the module configuration. After selecting the preset, you must press the
pushbutton before the store will take place. You can abort the operation by
pressing the pushbutton when Cancel is displayed.
This control is used to initiate a store of the current card configuration into
one of the user presets
Use the toggle switch to select the preset location where you want to store
the module configuration. After selecting the preset, you must press the
pushbutton before the store will take place. You can abort the operation by
pressing the pushbutton when Cancel is displayed.
This control is used to enable or disable the recall of parameter store with
each input and output combination. Each input and output combination
stores all the card parameters. During any standard change the set is
recalled. For a preset recall this causes a conflict is which parameter sets
have priority. Disabling this ensure all the preset recall parameters take
effect.
This control is used to set which preset will be recalled by the respective
GPI input is closed to ground. To disable a GPI input set it to Off.
This control is used enable the active display of various video parameters
on the OSD output when the menus are not being displayed.
Revision 0.2
7700 MultiFrame Manual
7710UC-KF HD Key/Fill Up Converter
7710UC-KF-19

Advertisement

Table of Contents
loading

This manual is also suitable for:

7710uc-kf

Table of Contents