6.9.

UTILITIES

The Utilities menus are used to list the module firmware version, upgrade the firmware, and manage the
user presets. The chart below shows the items available in the Utilities menu. Sections 6.9.1 to 6.9.6 give
detailed information about each of the parameters.
Recall Preset
Store Preset
Upgrade
Status Window
GPI 3 enable
About...

6.9.1. Recalling Configurations to the User Presets or the Factory Preset

The 7710UC-HD modules provide ten user preset areas to store the complete set of controls from the on
screen menu.
Utilities
Recall preset
Cancel
Factory
1 to 10
The current state of the card will be forgotten if it has not been saved to a preset
before a recall is performed.
There will be a slight disturbance in the operation of the card and the on-screen
display while the new preset is being recalled.
Used to recall the current module configuration from one of the user presets
or to reset the module to its factory preset condition.
Used to store the current module configuration to one of the user presets.
Used to upgrade the firmware in the module.
Used to enable or disable the on screen status window
Used to enable or disable support for GPI 3
Shows the firmware version of the module.
This control is used to initiate a recall of the current card configuration from
one of the user presets or from the factory preset.
Use the toggle switch to select the preset you wish to recall. After selecting
the preset, you must press the pushbutton before the recall will take place.
You can abort the operation by pressing the pushbutton when Cancel is
displayed.