7.4.3.4. Set The Pan-Scan Output Line Number
ARC Control
SMPTE 2016 Setup
Pan-Scan output line
12
9 to 19
7.4.3.5. Set The Handling Of Shoot And Protect
ARC Control
SMPTE 2016 Setup
Shoot and Protect
Use
ignore
7.4.3.6. Set The Read Pan-Scan Data Set ID
ARC Control
SMPTE 2016 Setup
Read Pan-Scan data
set ID
Any
1 to 254
1
7.4.3.7. Set The Write Pan-Scan Data Set ID
ARC Control
SMPTE 2016 Setup
Write Pan-Scan data
set ID
1 to 254
1
7710ARC Series - SD Aspect Ratio Converter
This control determines what line the Pan-Scan VANC embedder will
use.
The range of this parameter is 9 to 19.
Some AFD codes describe two different image configurations. This
control selects if the shoot and protect area should be used to
determine the location of the input image. This is also called the
"alternate centre".
For example, if AFD code specifies a letterbox 16:9 image with
alternate 14:9 centre cut, setting this control to "ignore" will result in the
letterbox 16:9 image being used as the input image area. Setting it to
"use" will result in the 14:9 area in the centre being used as the input
image area.
This control is used to select the Data Set ID to extract from incoming
Pan-Scan packets.
The ID value of 1 is used to indicate a universal or generic Pan-Scan
data set. The ID values from 2 to 63 may be assigned by SMPTE to
indicate specific Pan-Scan data sets. The ID values from 64 to 254 may
be defined privately.
Select any to respond to the first Pan-Scan data set encountered in the
incoming packets
This control is used to select the Data Set ID used when embedding a
Pan-Scan packet.
The ID value of 1 is used to indicate a universal or generic Pan-Scan
data set. The ID values from 2 to 63 may be assigned by SMPTE to
indicate specific Pan-Scan data sets. The ID values from 64 to 254
maybe defined privately.
Revision 1.1
7700 MultiFrame Manual