This places the unit in programming mode and opens its serial port to communicate with the WINISP
program. The front panel display shows Program Mode... Proceed to section 4.3.3 for information about
uploading the firmware using WINISP.
4.3.2.2.
Jumper Method
This method should only be attempted if the present software in the unit is not functioning sufficiently
enough to allow the user to access the UPGRADE FIRMWARE item on the Setup menu. This method
requires the unit to be powered down, the top cover removed, and the jumpers J27 and J11 on the Mid
plane board be placed in the programming position. Then reapply power to the unit and the unit should
automatically enter programming mode. Proceed to section 4.3.3 for information about uploading the
firmware using WINISP. When finished programming the unit, power down the unit, return the jumpers to
their original positions before re powering up the unit.
4.3.3. Programming the MCU Using WINISP
Start the WINISP application.
4.3.3.1.
WINISP Configuration Setup
Configure the WINISP software by selecting the following items in the Parameters boxes that are coloured
yellow.
1. Set the Chip setting to "89C51RC+".
2. Set the communications port to the port you have your straight through downloading serial cable
connected to.
3. Set the Osc frequency to 11 to match the internal crystal value of 11.05MHz.
When you are finished the parameters box should look like this:
TECHNICAL DESCRIPTION
HD9510UC High Definition Upconverter Manual
J27
J11
Programming
Figure 4-1:Configuring the Programming Jumpers
Revision 1.1.1
J27
J11
Normal Operation
Page 4-7