Bosch Solution 16i Installation Manual page 104

Hide thumbs Also See for Solution 16i:
Table of Contents

Advertisement

Solution 16i
Installation Manual
Comms > Dialler Reporting >
Status Route
(*** System Wide Parameter ***)
00 = Report Events To Log Only
01 = Report Events To Destination 1 + Log
02 = Report Events To Destination 2 + Log
03 = Report Events To Destination 1 & Destination 2 + Log
04 = Report Events To Dest 2 If Dest 1 Fails + Log
This menu sets the report destination that will be used to
send all system event reports.
1) Enter your Installer PIN + [MENU].
2) Enter [5] + [4] + [3] + [OK]. The keypad will display
the current Status Route.
3) Use the numeric keys to enter the Status Route
required, then press [OK] to save and exit or press
[MENU] to exit without saving.
Comms > Dialler Reporting >
Emergency Route
(*** System Wide Parameter ***)
00 = Report Events To Log Only
01 = Report Events To Destination 1 + Log
02 = Report Events To Destination 2 + Log
03 = Report Events To Destination 1 & Destination 2 + Log
04 = Report Events To Dest 2 If Dest 1 Fails + Log
This menu programs the destination that all keypad
emergency alarms are reported.
(*** System Wide Parameter ***)
1) Enter your Installer PIN + [MENU].
2) Enter [5] + [4] + [4] + [OK]. The keypad will display
the current Emergency Route.
3) Use the numeric keys to enter the Emergency Route
required, then press [OK] to save and exit or press
[MENU] to exit without saving.
9-14
Comms Programming
L543
MENU 5-4-3
d= 01
L544
MENU 5-4-4
d= 01
Comms > Dialler Reporting >
Swinger Dialler
0
1
(*** System Wide Parameter ***)
Swinger Dialler can be used to prevent a faulty or run-
a-way PIR from continually re-triggering the zone and
reporting to the base station.
The Swinger Dialler count sets the maximum number of
times an individual zone can trigger an alarm during the
current arming cycle before it is locked out.
If this option is not programmed, the panel will continue
to report the alarm signal until the system or area is
disarmed.
Only zones that have been programmed for Lockout
Dialler in MENU 3-1-7 — Report Options will follow the
Swinger Dialler count.
1) Enter your Installer PIN + [MENU].
2) Enter [5] + [4] + [5] + [OK]. The keypad will display
the current swinger dialler count.
3) Using the numeric keys, enter the new Swinger
0
1
Dialler count then press [OK] to save and exit or
press [MENU] to exit without saving. Valid entries
are 0 - 15 / 0 = disabled.
Comms > Dialler Reporting >
Burg Report Delay
(*** System Wide Parameter ***)
This menu programs how long the panel will delay
reporting Burglary alarm reports. Only burglary (non-
fire) zones that have been programmed for Delay Report
in MENU 3-1-7 — Report Option will follow the Burglary
Report Delay time.
1) Enter your Installer PIN + [MENU].
2) Enter [5] + [4] + [6] + [OK]. The keypad will display
the current burglary report delay time.
3) Using the numeric keys, enter the new report delay
time then press [OK] to save and exit or press
[MENU] to exit without saving. Valid entires are 0
to 255 seconds
L545
MENU 5-4-5
d= 06
L546
MENU 5-4-6
0
SECONDS
d= 000
Bosch Security Systems 09/11 BLCC500I
0
6