T
he Solution 16i has a built in dialler that connects
directly to a standard PSTN telephone line. To program
the dialler you must set the telephone number to dial and
then the reporting format to send the information in.
The command menu allows you to set the Domestic
Numbers, initiate a Solution Link Upload / Download
session, turn on/off call forwarding.
There are two independent reporting routes that define
where a reportable event should be sent, by default all
events will report through route 1. Reportable events in
the system are categorised into Alarm, System, Emergency,
Open/Close and Test. This means that you are able to steer
these different event categories to different report routes.
A report route is just like an independent dialler, it has
its own primary and secondary telephone numbers and
reporting format.
Example: Route 1 = CID, Route 2 = SMS
If you set the reporting route for Open/Close as Route 2
and all other events to Route 1, then all reports will be sent
to route 1 in Contact ID format and then all open close
reports will be sent through SMS. This is very handy if you
want to monitor what time your children come home
from school or cleaners entering or leaving your premises.
Telephone numbers can be 32 digits long and characters
0-9 * # and , are supported with the comma representing a
2 second pause. Destination route 1 and route 2 both have
their own Primary and Secondary telephone numbers,
Domestic reporting has 3 telephone numbers and remote
access has one call back number.
There are two back to base monitoring formats called CID
and SIA, both formats are all predefined so the system will
always send the same reporting code for the same event.
The type of zone selected under zone type automatically
determines the reporting code to the base station. If a
zone is defined as Medical then when it goes into alarm
the report will be Medical Alarm, if a zone is programmed
as a Fire zone then the report will automatically be Fire
Alarm.
Bosch Security Systems 09/11 BLCC500I
Comms Programming
CO M M S P R O G R A M M I N G CO M M A N D S
Comms > Commands >
Domestic Number
Domestic reporting allows the control panel to send
reports to 3 different personal telephone numbers (eg.
mobile telephone numbers). Each telephone number has
a maximum of 32 digits.
A telephone call needs to be acknowledged by the user
that answers the incoming call by pressing [#] on their
telephone. If the user fails to acknowledge the call, the
control panel will make another attempt to report until
the maximum number of call attempts are reached.
1) Enter your Installer PIN or Master PIN + [MENU].
2) Enter [5] + [0] + [0] + [OK].
If the control panel is not configured to report via
domestic format, the keypad will display the
following:
If the control panel has been configured to report via
domestic format, the keypad will display information
for telephone number 1.
3) Using the numeric keys, enter all of the digits of the
first telephone number that the control panel will
call.
You can change a single digit by scrolling the
cursor left [←] and right [→]. For special characters
(eg. Pause = P, A = *, H = # etc), use the [↑] and [↓] keys.
To clear or delete all numbers from the current cursor
position to the right, press the [OFF] key.
S E C TI O N 9
Set-Ph
-
MENU 5-0-0
NO Opt
Ph1 ?
9-1