Bosch Solution 16i Installation Manual page 86

Hide thumbs Also See for Solution 16i:
Table of Contents

Advertisement

Solution 16i
Installation Manual
1) Enter your Installer PIN + [MENU].
2) Enter [4] + [1] + [3] + [OK], then enter the output
number, then press [OK]. The keypad will display
the current output polarity.
3) Use the numeric keys and enter the Output Polarity
required then press [OK] to save and exit or press
[MENU] to exit without saving.
Normally Open Going Low
Output is normally open circuit and switches to GND
when the event occurs. The output will reset when the
output event restores. Time parameters do not apply to
this polarity type.
Normally Open Going Low With Pre Delay
Output is normally open circuit and switches to GND
when the event occurs provided the time parameter has
expired. The output will reset when the output event
restores. Time parameters will only set the Pre Delay
when this polarity is selected.
Normally Open Latching Low
Output is normally open circuit and will switch to zero
volts when the event occurs. The output can only be
reset manually using the Output Command Menu.
Normally Open Pulsing Low
Output is normally open circuit and will pulse LOW when
the event occurs. The output will reset when the output
event restores. Use the Time Parameter to set the pulse
duration.
Normally Open One Shot Low
Output is normally open circuit and switches to GND
when the event occurs. The output will only reset
when the time specified in the Time Parameter expires.
The output will run for the full duration and cannot be
manually reset.
Normally Open One Show Low + Retrigger
Output is normally open circuit and switches to GND
when the event occurs. The output will retrigger each
time the event occurs. The output will reset when the
one shot time has expired.
This polarity is ideally suited for security lighting control.
A sensor can be used to trigger an output event and then
each time the sensor triggers, the output will operate.
The light will turn off when the one shot timer expires.
Normally Open One Shot Low + Reset
Output is normally open circuit and will switch to GND
when the event occurs. The output will reset when the
8-8
Output Programming
d= 00
one shot timer expires or when the event has restored.
This means the operation of the output can be shortened
based on the event and or the programmed time
parameter.
Normally Low Going Open
Output is normally GND and will switch to open circuit
when the event occurs. The output will reset when the
output event restores. Time parameters do not apply to
this polarity type.
Normally Low Going Open With Pre Delay
Output is normally GND and will switch to open circuit
when the event occurs provided the time parameter has
expired. The output will reset when the output event
restores. Time parameters will only set the Pre Delay
when this polarity is selected.
Normally Low Latching Open
Output is normally GND and will switch to open circuit
when the event occurs. The output can only be reset
maually usning the output Command Menu.
Normally Low Pulsing Open
Output is normally LOW and will pulse OPEN when the
event occurs. The output will reset when the output
event restores. Use the Time Parameter to set the pulse
duration.
Normally Low One Shot Open
Output is normally LOW and will switch to open circuit
when the event occurs. The output will only reset
when the time specified in the Time Parameter expires.
The output will run for the full duration and cannot be
manually reset.
Normally Low One Show Open + Retrigger
Output is normally LOW and will switch to open circuit
when the event occurs. The output will retrigger each
time the event occurs. The output will reset when the
one shot time has expired.
Normally Low One Shot Open + Reset
Output is normally LOW and will switch to open circuit
when the event occurs. The output will reset when the
one shot timer expires or the event has restored. This
means the operation of the output can be shortened
based on the event and or the programmed time
parameter.
Horn Speaker (Output 1 or 2 Only)
This polarity can only be used for Output 1 and Output 2
when a horn speaker has been connected.
Toggle On / Toggle Off
This polarity allows the output to turn on when the event
occurs. The output will toggle off when the event occurs
again. This polarity does not follow any time parameters.
Bosch Security Systems 09/11 BLCC500I