Bosch Solution 16i Installation Manual page 61

Hide thumbs Also See for Solution 16i:
Table of Contents

Advertisement

Areas > Properties >
Reporting Options
1
Report PIN Retry
2
Report Exit Error
3
Smart Lockout
4
Reserved
5
Cancel Reports
6
Reserved
7
Open / Close Reports For Part On
8
Open / Close Reports Only After Alarm
The above options are programmable per area.
1) Enter your Installer PIN + [MENU].
2) Enter [2] + [1] + [4] + [OK].
3) Enter the area required, then press [OK].
4) Use the keys [1] to [8] to toggle on or off the option
required.
1 2
5) Repeat Step 4 until all options are programmed as
required, then press [OK] to save and exit or press
[MENU] to exit without saving.
Report PIN Retry
When the PIN Retry Count as programmed in MENU 1-5-
1 is reached a Wrong Code Entry alarm report will be
sent to the Control Room.
Report Exit Error
This option allows the system to report and Exit Error
Alarm.
An exit error occurs when an entry/exit delay zone
becomes unsealled during exit delay time and remains
unsealled at the end of exit delay time. If this happens,
the entry delay will start. If the area is not turned off
(disarmed) before the entry delay time expires an Exit
Error alarm report will be sent.
Smart Lockout
Smart lockout allows and previously locked zones to
reactivate during the siren run time when a new alarm
event occurs.
Cancel Reports
When set, a Cancel report will be sent if a user disarms
the area before the siren timer expires.
Open/Close Reports For Part On
When set, the panel will Send Open or Close reports
when the system is armed in Part On mode.
Bosch Security Systems 09/11 BLCC500I
L214
MENU 2-1-4
-Bit-
5
Solution 16i
Open/Close Reports Only After Alarm
When set, the panel will send a single Open / Close
report if a previous alarm has occured. This report will
Y
be sent for all users regardless of whether or not they
have been programmed to send Open/Close reports.
Y
N
Areas > Properties >
N
Strobe Trigger
Y
1
Audible Burglary Alarm
N
2
Silent Burglary Alarm
N
3
Fire Alarm
N
4
Arm / Disarm Flash Via RF Keyfob
5
Arm / Disarm Flash Via Keyswitch or PGM Input
6
Reserved
7
24-Hour Alarm
8
Reserved
Programming any of these options allow the strobe
output to operate when the corresponding event
occurs. The strobe light must be connected to an output
programmed as a Event Type 48 for it to operate. See
Section 8 — output Programming for more Information
on output event types.
1) Enter your Installer PIN + [MENU].
2) Enter [2] + [1] + [5] + [OK].
3) Enter the area required, then press [OK].
4) Use the keys [1] to [8] to toggle on or off the option
required.
5) Repeat Step 4 until all options are programmed as
required, then press [OK] to save and exit or press
[MENU] to exit without saving.
Audible Burglary Alarm
When selected, the panel will activate the strobe output
when an audible burglary zone has triggered an alarm.
Silent Burglary Alarm
When selected, the panel will activate the strobe output
when a silent burglary zone has triggered an alarm.
Fire Alarm
When selected, the panel will activate the strobe output
when a zone programmed as fire (audible or silent) has
triggered an alarm.
Installation Manual
Area Programming
-Bit-
1
3
7
L215
MENU 2-1-5
Y
N
Y
N
N
N
Y
N
6-7