Connecting Power To The Panel; Connecting The Battery; Ac Mains Transformer Option; Figure 6: Mw710 Configuration Examples - Bosch Solution 16i Installation Manual

Hide thumbs Also See for Solution 16i:
Table of Contents

Advertisement

Solution 16i
Installation Manual
When installing large modules you should fit 5
mounting clips as shown.
Clip 5 provides support under the main terminal
block only. No screw is fitted.
1
4
CABLE ENTRY (REAR)
MODULE
SPACE 2
CABLE ENTRY (REAR)
MODULE
SPACE 4
CABLE ENTRY (REAR)
1
MODULE
SPACE 6
4
When installing small modules, you should
fit 4 mounting clips as shown.

Figure 6: MW710 Configuration Examples

CO N N E C T I N G P O W E R TO T H E PA N E L
For normal operation, the panel requires both AC and DC
power sources. The AC source can be provided either
by an external adapter or by an internal transformer
depending on the model and country of sale.
When connecting using the A.C adapter, feed the cable in
to the enclosure and terminate the wires on the removable
terminal block supplied before connection it to the PCB.
If using a 3 wire Adaptor, then the earth wire should also
be terminated onto the terminal block. Always check the
orientation of the terminal block with the PCB markings
before connecting it to the PCB.
2-4
Installing the Hardware
2
MODULE
SPACE 1
5
3
MODULE
SPACE 3
MODULE
SPACE 5
2
MODULE
SPACE 7
3
CO N N E C T I N G T H E B AT T E R Y
The panel is supplied with a set of battey leads to suit
the chosen enclosure. Connect the Red Battery lead to
the Battery (+) terminal and the Black Battery lead to the
Battery (-) terminal on the PCB.
Once terminated onto the PCB connect the other end of
the leads to the battery paying attention to the polarity.
AC M A I N S T R A N S F O R M E R O P T I O N
On models with an internal transformer, a permanent
connection shall be made to the mains supply. See
Figure 8. This must be completed by a suitably qualified
electrician according to the applicable wiring standards
and regulations.
Next connect the transformer output wires (red) to the
removable terminal block supplied and then connect it
to the PCB. Always check the orientation of the terminal
block with the PCB markings before connecting.
For permanently connected equipment, a readily
i
accessable disconnect device shall be installed in a
Note
location near to the equipment.
Transformer Output
(Red Wires)
A
Transformer
D
(Blue Wires)
A
B
A = PCB Mounting Clip Holes
B
= Enclosure Mounting Holes
C
= Fused Terminal Block
D
= Transformer

Figure 7: Internal Transformer Connection Diagram

Wiring must be carried out by
a licensed electrician following
applicable wiring standards
Input
TRANSFORMER
220 - 240V A.C.
50-60Hz 150mA
FUSE
8AG - 250V
250mA MAX
NEUTRAL
EARTH
ACTIVE
C
Bosch Security Systems 09/11 BLCC500I