Bosch Solution 16i Installation Manual page 123

Hide thumbs Also See for Solution 16i:
Table of Contents

Advertisement

Devices > Ethernet >
Ethernet Options
1
Display Faults
2
Report Cable Lost
3
Report IP Conflict
4
Report Poll Fail
5
Reserved
6
Reserved
7
Reserved
8
Reserved
This menu option allows you to configure the various RF
receiver functions. Only one RF reciever can be fitted per
panel.
1) Enter your Installer PIN + [MENU].
2) Enter [6] + [6] + [9] + [OK].
The keypad will display the current options which are
selected or enabled.
1 2 3 4
3) Use the numeric keys [1] to [8] to turn on and off
the features as required. When the corresponding
number on the keypad is on then the option is
selected.
4) When all options are programmed, press [OK] to
save and exit, or press [MENU] to exit without
saving.
Display Faults
This option allows the keypad to display a trouble
condition if the control panel detects when the ethernet
module is missing, the module IP is changed, there is no
connection, there is an IP lockout or there is an IP conflict.
Report Cable Lost
This option allows the control panel to report when it
detects that the LAN cable is missing via the dialler.
Report IP Conflict
This option allows the control panel to report an IP
conflict via the dialler when it detects two computers
on the LAN or internet have been assigned the same IP
address.
Report Poll Fail
This option allows the control panel to report via the
dialler when the ethernet module fails to send a poll to
the base station.
» » E N D
Bosch Security Systems 09/11 BLCC500I
L669
MENU 6-6-9
-bit-
O F
S E C T I O N « «
Solution 16i
Y
Y
Y
Y
N
N
N
N
Installation Manual
Device Programming
10-11

Advertisement