3) Use keys [1] to [8] to toggle on or off the option
required.
1 2 3 4
4) Repeat Step 3 until all options are programmed as
required, then press [OK] to save and exit or press
[MENU] to exit without saving.
Lockout Dialler
Setting this option will enable Dialler Lockout
functionality for the respective zone(s). All zones in
the system can be individually programmed for Dialler
Lockout.
When enabled the zone will be allowed to transmit
alarm reports each time it is triggered provided that
the Swinger Dialler count has not been reached. If the
zone is triggered and the Swinger Dialler count has been
reached then the zone will become locked out and no
further reports will be sent for that zone. Dialler lockout
will be reset on the next arming cycle.
See MENU 5-4-5 — Swinger Dialler to set the number of
times a zone is allowed to trigger before being locked
out.
Report Alarm
Setting this option will enable the system to Report
Alarm events for the respective zone. All zones in the
system can be individually programmed to report alarms.
Report Trouble
Setting this option will enable the system to Report
Trouble events for the respective zone. A Trouble report
will be sent if the zone is left unsealled at the end of
exit time. All zones in the system can be individually
programmed to report trouble events.
Report Bypass
Setting this option will enable the system to Report Zone
Bypass events for the respective zone. A Bypass report
will be sent at the end of exit time for zones which have
been manually bypassed. All zones in the system can be
individually programmed to report Zone Bypass events.
Report Restores
Setting this option allows the system to send Restore
reports for zones that have already sent a previous alarm
or trouble report on the same arming cycle.
1) Burglary Zone alarms and troubles restore when
the zone reseals or the area is disarmed.
2) 24hr Zone alarms and troubles restore when the
zone reseals.
3) Bypassed Zone restore when the area is disarmed.
Bosch Security Systems 09/11 BLCC500I
-Bit-
7
Solution 16i
Installation Manual
Delay Report
Setting this option will cause the system to delay alarm
reports for the selected zone. This option can be enabled
to allow a user to enter their PIN and disable the report
in case they have caused a false alarm. If a PIN is not
entered within the delay time, the system will trigger the
sirens and send the report as normal.
See MENU 5-4-6 — Burg Report Delay and MENU 5-4-7
— Fire Report Delay to set the delay time.
If a PIN code is entered after the delay time has expired,
and the sirens are still sounding, the system will send the
Alarm report followed by a Cancel report.
Inputs > Zone Properties >
Zone Options
1
Lockout Siren
2
Silent Alarm
3
Inverted Seal
4
Bypass Allowed
5
Sensor Watch
6
Armed When in Part Mode 1
7
Reserved
8
Test On Exit
The above options are programmable per zone.
1) Enter your Installer PIN + [MENU].
2) Enter [3] + [1] + [8] + [OK], then enter the zone
number required and press [OK]. The keypad will
display the Zone Options for the currently selected
zone.
3) Use keys [1] to [8] to toggle on or off the option
required.
1 2 3 4
4) Repeat Step 3 until all options are programmed as
required, then press [OK] to save and exit or press
[MENU] to exit without saving.
Lockout Siren
Setting this option will enable Siren Lockout functionality
for the respective zone(s). All zones in the system can be
individually programmed for Siren Lockout.
When enabled the respective zone will be allowed to
cause the sirens to sound each time a new alarm is
triggered provided that the Swinger Siren count has not
been reached. If the zone is triggered and the Swinger
Siren count has been reached then the siren will become
locked out for that zone and no further siren activations
will occur from that zone. Only zones which have been
locked out are prevented from triggering the sirens.
Input Programming
L318
MENU 3-1-8
-Bit-
7
Y
N
N
Y
N
Y
N
Y
7-9

Advertisement

Table of Contents
loading

Table of Contents