Bosch Solution 16i Installation Manual page 59

Hide thumbs Also See for Solution 16i:
Table of Contents

Advertisement

Exit Time Restart
The exit delay timer will restart (once per arming cycle)
when the same entry/exit delay zone is faulted a second
time during exit delay (eg. If an entry/exit delay zone is
unsealled, restored and unsealled a second time during
exit delay = exit time restart).
Reset Alarm Memory On Disarm
Clears all alarm memories displayed on the keypad when
a user has turned the corresponding area off. If this
option is not set, alarm memory will continue to display
until the user has turned the corresponding area 'on'
again.
Duress Allowed
If a user is being forced to turn off the security system
under duress they can disarm the system and initiate a
silent duress alarm.
To trigger the duress alarm enter your PIN then repeat
the last two digits of your PIN before pressing [ON], [OFF],
or [OK] key.
Example:
If your PIN is 2580, to send a duress report when the area
is off,
Enter, [2] + [5] + [8] + [0] + [8] + [0] + [OK] or [ON].
If your PIN is 2580, to send a duress report when the area
is on,
Enter, [2] + [5] + [8] + [0] + [8] + [0] + [OFF].
Acknowledge All Faults
If this option has been programmed, the control panel
will force a user to acknowledge each trouble condition
even though the trouble condition has already cleared.
If this option is not programmed, any trouble condition
that occurs will not have to be acknowledged if it has
already been rectified or cleared.
Single Button Arming Allowed – All On
This option allows users to simply press the ON key
to turn the area ON. All zones being armed must be
sealled. If open and close reports are programmed, the
user ID number will report as 000.
Single Button Arming Allowed – Part On
This option allows users to simply press the Part On key
to turn the area Part On. All zones in the being armed
must be sealled. If open and close reports in Part Mode
are programmed, the user ID number will report as 000.
Bosch Security Systems 09/11 BLCC500I
Solution 16i
Installation Manual
Link To Common Area
This option causes the selected area or areas to control
the common area. If this option is not selected for an
area then it will be able to operate independant of the
common area. See MENU 7-7-1 — Area Options to
enable the common area.
Single Button Part Off
This option allows users to disarm from Part Mode or Part
Mode 2 simply by pressing the OFF key. This function will
only work if there are no alarms in effect, and the entry
timer is not running.
Areas > Properties >
Input Options
1
Non Sequential Handover (Entry Path)
2
Pulse Count Handover Allowed
3
Senior Watch
4
Reset Smoke On Arming
5
Reserved
6
Reserved
7
Reserved
8
Reserved
The above options are programmable per area.
1) Enter your Installer PIN + [MENU].
2) Enter [2] + [1] + [2] + [OK].
3) Enter the area required, then press [OK].
4) Use the keys [1] to [8] to toggle on or off the option
required.
1 2
5) Repeat Step 4 until all options are programmed as
required, then press [OK] to save and exit or press
[MENU] to exit without saving.
Non Sequential Handover
With Non-Sequential entry path you can trigger
handover zones in any order provided that an entry delay
zone was triggered first.
If this option is not programmed, handover zones must
be triggered in numerical sequence provided that an
entry delay zone was triggered first.
If a handover zone is triggered before an entry delay
zone is triggered an instant alarm will occur.
Area Programming
L212
MENU 2-1-2
-Bit-
4
Y
Y
N
Y
N
N
N
N
6-5

Advertisement

Table of Contents
loading

Table of Contents