Bosch Solution 16i Installation Manual page 85

Hide thumbs Also See for Solution 16i:
Table of Contents

Advertisement

56 – Follow PIN
This event type will cause the output to operate when a
specified user PIN is entered via the keypad or when the
corresponding user's keyfob or token is used.
You should program the User whose PIN is to be followed
into the Event Assignment for this output.
57 – Part Entry Time
This event type will cause the output to operate when
the Part Entry timer is active and will reset when Part
Entry time expires.
58 – Schedule
This event type will cause the output to operate when a
specific schedule occurs. The output requires a schedule
to be programmed to operate an output. The output
programmed to follow the schedule must match that
programmed in the schedule index.
59 – Keypad Temperature Alarm
This event type will cause the output to operate when
the keypad temperature increases above the maximum
or falls below the minimum set temperature. The output
will reset when the temperature reads between the
maximum and minimum values.
See MENU 7-7-3 — Keypad Hi/Lo Temp in Section 11 -
System Programming
60 – Access Group
This event type will cause the output to operate when
a user assigned to the same Access Group swipes their
token. The prox reader must be assigned to the same
Access Group as the Output and User.
The Event Assignment is the Access Group Number.
Bosch Security Systems 09/11 BLCC500I
Solution 16i
Installation Manual
Outputs > Properties >
Event Assignment
This menu allows you to assign an Output event to an Area
number (1 to 4), a User number (1 to 48), a Zone number
(1 to 16) or a Group number (1 to 8) that the output will
follow. Programming a zero will assign the output event
to follow any area, user, zone or access group depending
on the event type.
Refer to Output Event Type Table for a complete listing of
available options.
1) Enter your Installer PIN + [MENU].
2) Enter [4] + [1] + [2] + [OK], then enter the output
number you want to change and press [OK].
3) Using the numeric keys, enter the Output Event
Assignment required, then press [OK] to save and
exit or press [MENU] to exit without saving.
Outputs > Properties >
Output Polarity
00 = Normally Open, Going Low
01 = Normally Open, Going Low With Pre Delay
02 = Normally Open, Latching Low
03 = Normally Open, Pulsing Low
04 = Normally Open, One Shot Low
05 = Normally Open, One Shot Low + Retrigger
06 = Normally Open, One Shot Low + Reset
07 = Normally Low, Going Open
08 = Normally Low, Going Open With Pre Delay
09 = Normally Low, Latching Open
10 = Normally Low, Pulsing Open
11 = Normally Low, One Shot Open
12 = Normally Low, One Shot Open + Retrigger
13 = Normally Low, One Shot Open + Reset
14 = Horn Speaker (Output 1 and/or 2 Only)
15 = Toggle On / Toggle Off
The output polarity programs how the output will operate.
Only one option (0 – 15) can be programmed per output.
See the Output Polarity description for more detailled
information.
Output Programming
L412
MENU 4-1-2
0
d= 00
L413
MENU 4-1-3
0
0
0
0
8-7