Calibration and Testing
NOTE: When this warning message
appears, the Side Sensor or the CPU
Board replacement is recommended.
4. Confirm that the non-paper calibration is com-
pleted with a check mark (Figure 6-31 a) appear-
ing next to "
Calibration without paper

Figure 6-31 Non-Paper Calibration Completion

a
Figure 6-31 Non-Paper Calibration Completion
5. The "
Set a reference paper and click the start but-
" message dialogue box will appear. Place the
ton.
KS-091 Reference Paper into the DBV-500
Device and close the Upper Guide, then click the
"
"
button (Figure 6-32 a).
OK

Figure 6-32 Placing Reference Paper Message

Figure 6-32 Placing Reference Paper Message
6. Confirm that the Upper Guide is locked firmly
and click the "
Start
begin the Reference Paper Calibration.

Figure 6-33 Reference Paper Calibration

a
Figure 6-33 Reference Paper Calibration
7. Confirm the "
Calibration with paper
is completed with a check mark (Figure 6-35 a)
appears next to "
P/N 960-100933R_Rev. 2 {EDP #233449}
DBV™ Series DBV-500 Banknote Acceptor
" text line.
a
"
button (Figure 6-33 a) to
" calibration
" text line.
Calibration with paper
8. Confirm the "
Remove a reference paper and
click start button.
Remove the KS-091 Reference Paper and click
the "
"
button (Figure 6-34 a).
OK
Figure 6-34 Removing Reference Paper Mes-
sage

Figure 6-34 Removing Reference Paper Message

9. Confirm that the Upper Guide is locked firmly
and click the "
Start
begin the second Non-paper Calibration.

Figure 6-35 Second Non-Paper Calibration

a
b
Figure 6-35 Second Non-Paper Calibration
10. When the second Non-paper Calibration is com-
pleted, the "Maintenance Calibration Tool" dia-
logue screen appears to change the Serial
Number. When using the default Serial Number,
click the "
"
No
ish the calibration.

Figure 6-36 Serial Number Change Dialogue

b
Figure 6-36 Serial Number Change Dialogue
To change the Serial Number, click the "
button (Figure 6-36 b). The
screen will appear. Type in the
BER SETTING
desired 10-digit (Maximum: 12-digit) Serial
Number into the Serial No. text box (Figure 6-37
a), then click the "
© 2020 JAPAN CASH MACHINE CO., LTD.
6 - 7
Section 6
" message dialogue box appears.
a
"
button (Figure 6-35 b) to
button (Figure 6-36 a) to fin-
a
YES
SERIAL NUM-
"
button (Figure 6-37 b).
OK
"