Calibration and Testing

White Level Test

To perform the DBV-500 White Level Test, 
proceed as follows:
1. Click the White Level Test Button (Figure 6-43
a).

Figure 6-43 White Level Test Button

Figure 6-43 White Level Test Button
2. Confirm that the "
appears (Figure 6-44).
3. Insert the KS-091 Reference Paper while refer-
ring to the instruction shown on the Screen. 
Firmly close the Upper Guide until it "clicks"
into place, and ensure that both sides are tightly
closed and locked, then click the "
ton (Figure 6-44 a) to begin the White Level Test.

Figure 6-44 White Level Test Start Button

a
Figure 6-44 White Level Test Start Button
4. Once the White Level Test is completed, "
Paper Level Check Succeeded
message appears on the right column of the
Screen. 
Click the "
"
Exit
end the White Level Test.

Figure 6-45 White Level Test Completion

a
Figure 6-45 White Level Test Completion
P/N 960-100933R_Rev. 2 {EDP #233449}
DBV™ Series DBV-500 Banknote Acceptor
a
" Screen
WHITE LEVEL TEST
"
But-
Start
White
" (Figure 6-45 a)
Button (Figure 6-45 b) to
b

Performance Tests

This section provides Performance Testing instructions
for the DBV-500 Unit. There are two (2) Performance
Test methods:

Performance Test using a PC

Performance Test without a PC
Choose a Performance Test procedure by selecting
the one related to the particular circumstance
desired.
Performance Test Using a PC
To perform the DBV-500 Performance Tests using
a PC, proceed with the following steps. See Figure
6-1 and Figure 6-2 to confirm the necessary tools
and connections required.

Performance Test Preparation

To prepare the Performance Test, proceed as fol-
lows:
1. Remove electrical power from the DBV-500
Unit.
2. Set DIP SW1 #8 to ON (Figure 6-46).

Figure 6-46 DIP SW1 Setting

ON
1
2
3
Figure 6-46 DIP SW1 Setting
3. Apply electrical power to the DBV-500 Unit.
Confirm the LED flashes at a Green color rate
when the DBV-500 Unit is in Test Mode.
4. Connect the PC and the DBV-500 Unit using the
USB Cable.
5. Launch the "JCM Tool Suite Standard Edition"
Application and confirm that the Initial Screen
shown in Figure 6-47 appears.
6. Click the "Service Mode" Pull-down Menu, and
select "Performance Test" (Figure 6-47 a).
Figure 6-47 JCM Tool Suite Standard Edition
Initial Screen
a
Figure 6-47 JCM Tool Suite Standard Edition 
Initial Screen
7. Confirm that the Performance Test Main Screen
appears (Figure 6-48).
© 2020 JAPAN CASH MACHINE CO., LTD.
6 - 9
Section 6
4
5