9 | Brake control and temperature detection

9 Brake control and temperature detection
X1C
2
4
6
1
3
5
Tab. 18: Assignment of the terminal block X1C
9.1 Brake control
CAUTION
Specification brake/relay output
Connection
9.2 Temperature detection
DANGER
34
PIN
Name
1
BR+
2
BR-
3
Reserved
4
Reserved
5
TA1
6
TA2
Incorrect dimensioning of the brake may cause malfunctions
Brake does not release or only with delay
a) Choose the input voltage tolerance of the brake corresponding to the tolerance
of the output voltage.
b) Use an auxiliary relay or contactor if necessary.
Name
Function
Output voltage (DC)
maximum output current
Others
1
X1C
2
Fig. 6: Connection of a brake
Electric shock by sensors without protective separation!
a) Only use sensors with basic insulation.
Notes
Brake control / output
Brake control / output
Temperature detection / input +
Temperature detection / input -
BR+ (X1C.1); BR- (X1C.2)
Output to supply a brake or relay.
minimum P24Vin – 2.4V
maximum P24Vin
2 A
Internal free-wheeling path; internal filter circuit;
short-circuit proof
+
-
ma_dr_f6-cu-a-inst-20118593_en
KEB Automation KG
U
= 24 V
_dc
I
= 2 A
_max