Diagnosis/Visualisation X4A | 6; Assignment Of The Terminal Strip X4A; Fig. 1 Pin Assignment Socket D-Sub-9 (Top View); Tab. 11 Serial Interfaces - KEB COMBIVERT F6 Instructions For Use Manual

Hide thumbs Also See for COMBIVERT F6:
Table of Contents

Advertisement

6 Diagnosis/visualisation X4A
NOTICE
6.1 Assignment of the terminal strip X4A
ma_dr_f6-cu-a-inst-20118593_en
The integrated serial interface provides the following functions:
• Parameterization of the device with the KEB software COMBIVIS.
• Connection for operator keyboard/display.
• Connection for Bluetooth adapter.
• DIN66019II as communication protocol.
Interface
RS485
RS232
Tab. 11: Serial interfaces
Name
Bluetooth adapter
Tab. 12: Accessories
Name
RS232 PC inverter (SubD-9 coupling -
SubD-9 plug)
RS232/USB (USB serial converter in-
clusive cable)
Tab. 13: Connecting cable
No potential separation of the diagnostic interface to the control voltage!
Malfunction or defect can be caused by voltage differences.
a) Install equipotential bonding conductor if voltage differences > common-mode
voltage range.
XML file required for COMBIVIS 6.
a) A current XML file is required for the operation with COMBIVIS 6.
b) The download can be done directly from COMBIVIS 6 while an Internet con-
nection is present.
Fig. 1: Pin assignment socket D-Sub-9 (top view)
1 reserved
3 RxD (RS232)
5 RxD-B (RS485)
7 DGND (reference potential)
9 TxD-B (RS485)

Diagnosis/visualisation X4A | 6

Specification
Common-mode voltage range 0...12 V
ANSI TIA/EIA-232
Material number
0058060-0060
Material number
0058025-001D
0058060-0040
5 4 3 2 1
4
2
1
5
3
9
8
7
6
9 8 7 6
2 TxD (RS232)
4 RxD-A (RS485)
6 reserved
8 TxD-A (RS485)
25

Advertisement

Table of Contents
loading

Table of Contents