Vcc - Led; Net St - Led; Dev St - Led; Opt - Led - KEB COMBIVERT F6 Instructions For Use Manual

Hide thumbs Also See for COMBIVERT F6:
Table of Contents

Advertisement

3.11.2 VCC - LED
3.11.3 NET ST - LED
3.11.4 DEV ST - LED
3.11.5 OPT - LED
Tip
ma_dr_f6-cu-a-inst-20118593_en
LEDs
Status
VCC
ready for operation
NET
ST
DEV
ST
OPT
Tab. 3: LEDs at power on
VCC
LED colour Description
off
-
Power supply of the control card switched off.
on
green
Control is supplied with 24 V.
Tab. 4: Function VCC LED
NET ST
LED colour Description
off
-
Device off or booting.
on
yellow
During switching on, if FPGA is booted.
Blink
various
depending on fieldbus => fieldbus interfaces.
code
Tab. 5: Function NET ST - LED
DEV ST
LED colour Description
OFF
-
Device off or in boot process.
ON
Red
Error
ON
Yellow
No error, DC bus not charged.
ON
Green
No error, ready for operation.
Flashing
Green
No error, serves to identify the device (fb.32).
Tab. 6: Function DEV ST - LED
OPT
LED colour Description
-
-
reserved for options.
Tab. 7: Function OPT - LED
The DEV ST and OPT LEDs can be re-programmed for diagnostic purposes
(i.e., the OPT LED could be programmed to represent the status of one of
the digital inputs).
Refer to the Configuration Handling parameters in the programming
manual.
Product description | 3
Note
Device is ready for operation and the LEDs start
with their normal function (approx. 3 s)
15