Brake Control And Temperature Detection For K- And A- Control; Specification And Connection Of The Brake Control; Figure 24: Assignment Of The Terminal Block X1C For K- And A-Control; Figure 25: Example For The Connection Of The Brake Output At X1C - KEB COMBIVERT S6 Series Instructions For Use Manual

Hide thumbs Also See for COMBIVERT S6 Series:
Table of Contents

Advertisement

brAKe cONTrOL AND TeMPerATUre DeTecTION fOr K- AND A- cONTrOL

4.3 brake control and temperature detection for K- and A- control
Figure 24:

4.3.1 Specification and connection of the brake control

Name
function
Output voltage
Maximum output current
Others
Figure 25:
X1c
PIN
1
2
3
4
2
4
6
5
6
1
3
5
Assignment of the terminal block X1C for K- and A-control
1
X1C
2
Example for the connection of the brake output at X1C
Name
Notes
BR+
Brake control / output +
BR-
Brake control / output -
Reserved
Reserved
TA1
Temperature detection / input+
TA2
Temperature detection / input-
24V
U
dc =
2A
I
_max =
BR+ (X1C.1); BR- (X1C.2)
Output to supply a brake
Minimum P24V_IN - 2.4 V
Maximum P24V_IN
2 A
Short-circuit proof, internal free-wheeling
path; internal filter switching