4 | Connection of the control
4.2.6.1.2 External supply
Specification external supply
22
Consumer
Control
Power unit
Consumer
Tab. 10: Calculation the current consumption
In order to calculate the input current, the currents of the power unit, control and
other loads must be added together. The actual current required can be used for
the consumers. The maximum current must not be exceeded.
Name
Terminals
Voltage
Current consumption
Connection of the external supply
The control card is supplied by an external 24 V voltage. An internal
supply via a voltage generated in the power section is not provided.
When using the
maintained until the function has been completed. Further information
in the programming manual under "Power-Off function".
Housing 2 / 3 / 4
Housing 6
Housing 7 / 8 / 9
Brake
Encoder
Digital output DO1
Digital output DO2
Voltage output 24Vout
Sum DO safety module
P24Vin, 0V
X2A.28 (P24Vin)
X2A.27 (0V)
DC 24 V (+20 % / -17 %)
Calculated value up to max. 4.8 A
28
X2A
27
-
+
Power-Off
function, the external 24V supply must be
ma_dr_f6-cu-a-inst-20118593_en
KEB Automation KG
Current consumption
0.6 A
0 A
0.6 A
1.0 A
Max. 2.0 A
Max. 0.5 A
Max. 0.1 A
Max. 0.1 A
Max. 0.1 A
Max. 0.4 A