Step A17 – Route new wires out of Silvia
In preparation for routing the wires, locate the 2 smaller rubber grommets, along with the
cable clamp and associated screw, washers, and nut, in your kit. Carefully work these
grommets into place in 2 of the holes in Silvia's base. The grommets fit very tightly into
these holes, so you will have to work them into place. Moistening the grommets with
water prior to installation helps. If you are very careful not to poke holes in the rubber, a
small screwdriver can help push them into place.
The following six (6) wires are going to be
routed out the base of Silvia, exiting through
the pump compartment at the rear of the
machine:
• Red and white low voltage DC control
wires from SSR (2 wires total)
• Black high voltage power wires from
main switch (2 wires total)
• Brown thermocouple cable (1 cable,
composed of 2 conductors)
• Green grounding wire (1 wire total)
Once you have the rubber grommets in place, feed those 6 wires through the grommets,
separating them into groups of 3. Group the 2 black high voltage wires with the green
grounding wire in one hole, and the thermocouple cable with the red and white low
voltage wires in the other.
(Run the grounding wire through first, followed by the black high voltage wires, thereby
maximizing clearance for passage of the ring terminal through the grommet opening).
See photo below for proper location of rubber grommets and wires (also note location of
mounting screw for cable clamp – we will install this in an upcoming step).
Copyright © 2006, 2008 MLG Properties, LLC