(2) Slave operation (when receiving slave address data (SVA0 match))
(a) Start - Address - Data - Data - Stop
<1> When WTIM0 = 0
ST
AD6 to AD0
1: IICS0 = 0001×110B
2: IICS0 = 0001×000B
3: IICS0 = 0001×000B
4: IICS0 = 00000001B
Remarks
<2> When WTIM0 = 1
ST
AD6 to AD0
1: IICS0 = 0001×110B
2: IICS0 = 0001×100B
3: IICS0 = 0001××00B
4: IICS0 = 00000001B
Remarks
318
C BUS MODE ( µ PD784225Y SUBSERIES ONLY)
2
CHAPTER 18 I
RW
AK
D7 to D0
1
: Always generated.
: Generated only when SPIE0 = 1
×: don't care
RW
AK
D7 to D0
1
: Always generated.
: Generated only when SPIE0 = 1
×: don't care
User's Manual U12697EJ3V0UM
AK
D7 to D0
AK
SP
2
3
AK
D7 to D0
AK
SP
2
3
4
4