Lenovo System x3100 M4 Installation And Service Manual page 381

Table of Contents

Advertisement

Prefix: PLAT ID: 0126
User Response
Make sure that DIMMs are installed and following the memory population chart in the system
publication. One of the DIMMs :
• 806f070d-0400ffff : Rebuild in progress for Array in system [ComputerSystemElementName]. (Drive
0)
This message is for the use case when an implementation has detected that an Array Rebuild is in
Progress.
May also be shown as 806f070d0400ffff or 0x806f070d0400ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0178
User Response
No action; information only.
• 806f070d-0401ffff : Rebuild in progress for Array in system [ComputerSystemElementName]. (Drive
1)
This message is for the use case when an implementation has detected that an Array Rebuild is in
Progress.
May also be shown as 806f070d0401ffff or 0x806f070d0401ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0178
User Response
No action; information only.
Appendix A. Integrated management module II (IMM2) error messages
367

Advertisement

Table of Contents
loading

This manual is also suitable for:

2582

Table of Contents