Lenovo System x3100 M4 Installation And Service Manual page 345

Table of Contents

Advertisement

• 806f010d-0401ffff : The Drive [StorageVolumeElementName] has been disabled due to a detected
fault. (Drive 1)
This message is for the use case when an implementation has detected a Drive was Disabled due to fault.
May also be shown as 806f010d0401ffff or 0x806f010d0401ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0164
User Response
1. Run the hard disk drive diagnostic test on drive n.
2. Reseat the following components: a. Hard disk drive (wait 1 minute or more before reinstalling
the drive) b. Cable from the system board to the backplane
3. Replace the following components one at a time, in the order shown, restarting the server each
time: a. Hard disk drive b. Cable from the system board to the backplane c. Hard disk drive
backplane (n = hard disk drive number)
• 806f010d-0402ffff : The Drive [StorageVolumeElementName] has been disabled due to a detected
fault. (Drive 2)
This message is for the use case when an implementation has detected a Drive was Disabled due to fault.
May also be shown as 806f010d0402ffff or 0x806f010d0402ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0164
User Response
1. Run the hard disk drive diagnostic test on drive n.
Appendix A. Integrated management module II (IMM2) error messages
331

Advertisement

Table of Contents
loading

This manual is also suitable for:

2582

Table of Contents