2. Check IBM support site for an applicable service bulletin or firmware update that applies to this
Processor error.
3. (Trained Service technician only) Replace the system board.
• I.2018002: [I.2018002] The device found at Bus % Device % Function % could not be configured
due to resource constraints. The Vendor ID for the device is % and the Device ID is %.
[I.2018002] The device found at Bus % Device % Function % could not be configured due to resource
constraints. The Vendor ID for the device is % and the Device ID is %.
Severity: Info
User Response:
Complete the following steps:
1. If this PCIe device and/or any attached cables were recently installed, moved, serviced or upgraded,
reseat adapter and any attached cables.
2. Check IBM support site for any applicable service bulletin or UEFI or adapter firmware update that
applies to this error. NOTE: It may be necessary to disable unused option ROMs from UEFI F1 setup
or ASU or using adapter manufacturer utilities so that adapter firmware can be updated.
3. Move card to a different slot. If slot not available or error re-occurs, replace adapter.
4. (Trained Service technician only) If adapter was moved to a different slot and error did not re-occur,
verify that this is not a system limitation and then replace the system board. Also, if this is not the
initial installation and the error persists after adapter replacement, replace system board.
• I.3818001: [I.3818001] The firmware image capsule signature for the currently booted flash bank is
invalid.
[I.3818001] The firmware image capsule signature for the currently booted flash bank is invalid.
Severity: Info
User Response:
Complete the following steps:
1. Reboot system. Will come up on backup UEFI image. Reflash the primary UEFI image.
2. If error does not persist no additional recovery action is required.
3. If error persists, or boot is unsuccessful, (Trained service technician only) Replace the system board.
• I.3818002: [I.3818002] The firmware image capsule signature for the non-booted flash bank is
invalid.
[I.3818002] The firmware image capsule signature for the non-booted flash bank is invalid.
Severity: Info
User Response:
Complete the following steps:
1. Reflash backup UEFI image.
2. If error does not persist no additional recovery action is required.
3. If error persists, or boot is unsuccessful, (Trained service technician only) Replace the system board.
• I.3818003: [I.3818003] The CRTM flash driver could not lock the secure flash region.
[I.3818003] The CRTM flash driver could not lock the secure flash region.
Severity: Info