Lenovo System x3100 M4 Installation And Service Manual page 364

Table of Contents

Advertisement

Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - CPU
SNMP Trap ID
40
CIM Information
Prefix: PLAT ID: 0062
User Response
1. Check the CPU LED. See more information about the CPU LED in Light path diagnostics.
2. Check for a server firmware update. Important: Some cluster solutions require specific code
levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest
level of code is supported for the cluster solution before you update the code.
3. Make sure that the installed microprocessors are compatible with each other.
4. (Trained technician only) Reseat microprocessor n.
5. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
• 806f050c-2001ffff : Memory Logging Limit Reached for [PhysicalMemoryElementName] on
Subsystem [MemoryElementName]. (DIMM 1)
This message is for the use case when an implementation has detected that the Memory Logging Limit
has been Reached.
May also be shown as 806f050c2001ffff or 0x806f050c2001ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0144
User Response
1. Check the IBM support website for an applicable retain tip or firmware update that applies to
this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs)
to a different memory channel or microprocessor.
3. If the problem follows the DIMM, replace the failing DIMM.
System x3100 M4 Installation and Service Guide