Lenovo System x3100 M4 Installation And Service Manual page 349

Table of Contents

Advertisement

Serviceable
Yes
Automatically notify support
No
Alert Category
System - Boot failure
SNMP Trap ID
25
CIM Information
Prefix: PLAT ID: 0186
User Response
1. Make sure the server meets the minimum configuration to start (see Power-supply LEDs).
2. Update the server firmware on the primary page. Important: Some cluster solutions require
specific code levels or coordinated code updates. If the device is part of a cluster solution, verify
that the latest level of code is supported for the cluster solution before you update the code.
3. (Trained technician only) Replace the system board.
• 806f0123-2101ffff : Reboot of system [ComputerSystemElementName] initiated by
[WatchdogElementName]. (Watchdog)
This message is for the use case when an implementation has detected a Reboot by a Watchdog
occurred.
May also be shown as 806f01232101ffff or 0x806f01232101ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0370
User Response
No action; information only.
• 806f0125-1d01ffff : [ManagedElementName] detected as absent. (Fan 1)
This message is for the use case when an implementation has detected a Managed Element is Absent.
May also be shown as 806f01251d01ffff or 0x806f01251d01ffff
Severity
Info
Serviceable
No
Appendix A. Integrated management module II (IMM2) error messages