Lenovo 5457 Installation And Service Manual page 417

Table of Contents

Advertisement

4. Remove components one at a time, restarting the server each time, to see if the problem goes
away.
5. If the problem remains, (trained service technician) replace the system board.
Firmware Error : Sys Boot Status :
• 806f000f-22010cff : CPU voltage mismatch detected on [ProcessorElementName]. (ABR Status)
This message is for the use case when an implementation has detected a CPU voltage mismatch with the
socket voltage.
May also be shown as 806f000f22010cff or 0x806f000f22010cff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - CPU
SNMP Trap ID
40
CIM Information
Prefix: PLAT ID: 0050
User Response
This is a UEFI detected event. The UEFI(POST) error code for this event can be found in the logged
IMM message text. Please refer to the UEFI(POST) error code in the "UEFI(POST) error code" section
of the Information Center for the appropriate user response. Firmware Error : Sys Boot Status :
• 806f000f-2201ffff : The System [ComputerSystemElementName] encountered a POST Error. (ABR
Status)
This message is for the use case when an implementation has detected a Post Error.
May also be shown as 806f000f2201ffff or 0x806f000f2201ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0184
User Response
Appendix A. Integrated management module II (IMM2) error messages