Microprocessor
bracket frame
Microprocessor
release lever
Figure 226. Microprocessor socket levers and retainer engagement for 5U server model with hot-swap power
supplies
7. Install the heat sink:
Attention: Do not touch the thermal material on the bottom of the heat sink. Touching the thermal
material will contaminate it. If the thermal material on the microprocessor or heat sink becomes
contaminated, contact your service technician.
a. Align the screw holes on the heat sink with the holes on the system board.
b. Tighten the screws with a screwdriver, alternating among the screws until they are tight. If possible,
each screw should be rotated two full rotations at a time. Repeat until the screws are tight. Do not
overtighten the screws by using excessive force.
System board
Figure 227. Heat sink installation for 5U server model with hot-swap power supplies
Lenovo System x3100 M5 Installation and Service Guide