11. Connect any required cables to the adapter. Route the cables so that they do not block the flow of air
from the system fan.
12. Install the air baffle (see
13. Install the side cover (see
14. Stand the server back up in its vertical position.
15. Install the bezel (see
16. Reconnect the external cables and power cords; then, turn on the attached devices and turn on the
server.
17. If you are replacing a ServeRAID adapter, import your RAID configuration to the replacement adapter as
a foreign configuration. See the ServeRAID-M Software User Guide at
entry/portal/docdisplay?lndocid=migr-5086126
To install a replacement adapter on the 5U server model with hot-swap power supplies, complete the
following steps. For 4U server models with non-hot-swap power supplies, please see the above sub-section.
Note: If your adapter was previously configured, back up or record its configuration information, if possible,
before replacing the adapter. See the documentation for your adapter for information and instructions.
1. Read the safety information in
2. Check the instructions that come with the adapter for any requirements, restrictions, or cabling
instructions. It might be easier to route cables before you install the adapter.
3. Follow the instructions that come with the adapter to set jumpers or switches, if any.
4. Touch the static-protective package that contains the adapter to any unpainted metal surface on the
server. Then, remove the adapter from the static-protective package. Avoid touching the components
and gold-edge connectors on the adapter.
5. Turn off the server and all peripheral devices; then, disconnect the power cords and all external cables.
6. Remove the expansion-slot cover by unscrewing the screw that secures it to the chassis. Store the
expansion-slot cover and screw in a safe place for future use.
Note: Expansion-slot covers must be installed on all vacant slots. This maintains the electronic
emissions standards of the server and ensures proper ventilation of server components.
7. Carefully grasp the adapter by the top edge or upper corner, and move the adapter directly from the
static-protective package to the expansion slot. Align the adapter with the expansion slot guides; then,
press the adapter firmly into the expansion slot.
Attention: Make sure that the adapter is correctly seated in the expansion slot before you turn on the
server. Incomplete installation of an adapter might damage the system board or the adapter.
"Replacing the air baffle" on page
"Replacing the side cover" on page
"Replacing the bezel" on page
"Safety" on page v
178).