Lenovo 5457 Installation And Service Manual page 455

Table of Contents

Advertisement

4. Check backplane cable connection.
5. Replace the RAID adapter.
6. Replace the hard disk drive that is indicated by a lit status LED.
• 806f050d-0405ffff : Array [ComputerSystemElementName] is in critical condition. (Drive 5)
This message is for the use case when an implementation has detected that an Array is Critical.
May also be shown as 806f050d0405ffff or 0x806f050d0405ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0174
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Check backplane cable connection.
5. Replace the RAID adapter.
6. Replace the hard disk drive that is indicated by a lit status LED.
• 806f050d-0406ffff : Array [ComputerSystemElementName] is in critical condition. (Drive 6)
This message is for the use case when an implementation has detected that an Array is Critical.
May also be shown as 806f050d0406ffff or 0x806f050d0406ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0174
Appendix A. Integrated management module II (IMM2) error messages
443

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x3100 m5

Table of Contents