Figure 3.3
Input-side AC
RCD
or
reactor 2
MCCB
U
X
Three-
Phase
V
Y
Power
W
Z
Supply
Reactor for
<2>
harmonic filter
Capacitor for
harmonic filter
Multi-function
digital inputs
(default setting)
<1> Do not use a line longer than 10 m to connect the input-side AC reactor and the converter.
<2> Use the specified AC reactor and harmonic filter module. Non-specified devices may cause erroneous operation.
<3> Do not use a DC bus line that is longer than 5 m to connect the converter and drive.
<4> Sequence the operation so that the converter starts operation before the drive when power is applied. Sequence the stopping
operation to turn off the drive first, then the motor, and finally the converter. Operating the drive without operating the converter or
turning off the power supply unit during operation may trigger a converter fault.
<5> Do not connect a power supply to the drive AC power supply terminals (R/L1, S/L2, and T/L3).
<6> The connections are shown for sequence connections with no-voltage contacts or NPN transistors for the sequence input signals
(S1 to S8). Use jumper S3 to select between Sink mode and Source mode. The default setting is Sink mode.
<7> Multi-function analog outputs work with devices such as analog frequency meters, ammeters, voltmeters, and wattmeters. They are
not intended for use as a feedback-type signal.
<8> When wiring the GA700, refer to
YASKAWA ELECTRIC SIEP C710656 06F YASKAWA Power Regenerative Converter - D1000 Technical Manual
Input-side
<1><2>
AC reactor 1
U
X
R/L1
V
Y
S/L2
Z
W
T/L3
U
V
W
Input-side AC
<2>
reactor 1
U
X
R1/L11
V
Y
X
Y
Z
S1/L21
W
Z
U
V
W
T1/L31
E
r1/ 11
1/ 21
t1/ 31
Control Circuit
S1
RUN-SB
S2
STOP
S3
External fault
S4
Fault reset
S5
(Reserved)
S6
(Reserved)
S7
(Reserved)
S8
External
Baseblock
Sink
SN
SC
Sink / Source mode
selection wire link
SP
(default: Sink)
<6>
+24 V
E(G)
Shield ground terminal
Power supply
+10.5 Vdc, max. 20 mA
+V
Analog Input 1
A1
(Reserved)
(Reserved)
A2
Analog Input 2
Analog Input 3
A3
(Reserved)
AC
-V
Power supply, -10.5 Vdc,
max. 20 mA
Termination resistor
(120 Ω, 1/2 W)
R+
R-
MEMOBUS/
S+
Modbus Communication
RS-422/RS-485
S-
max. 115.2 kbps
IG
shielded line
main circuit terminal
Figure 3.3 Standard Connection Diagram (example: model 4A0630)
.
Wiring on page 18
3.2 Standard Connection Diagram
+
Converter
D1000
-
Option card
connectors
CN5-C
CN5-B
CN5-A
Multi-function relay
M1
<4>
output (During Run 1)
250 Vac, max. 1 A
M2
30 Vdc, max. 1 A
(min. 5 Vdc, 10 mA)
Multi-function relay output
M3
(During MC on)
M4
250 Vac, max. 1 A
30 Vdc, max. 1 A
(min. 5 Vdc, 10 mA)
Multi-function relay output
M5
(Operation Ready)
M6
250 Vac, max. 1 A
30 Vdc, max. 1 A
(min. 5 Vdc, 10 mA)
MA
Fault relay output
MB
250 Vac, max. 1 A
30 Vdc, max. 1 A
MC
(min. 5 Vdc, 10 mA)
DIP Switch S1
V
I
Multi-function analog
output 1
FM
(Output frequency)
-10 to +10 Vdc (2 mA) or
4 to 20 mA
<7>
DIP
AM
Multi-function analog
Switch S2
output 2
(Output current)
-10 to +10 Vdc (2 mA) or
AC
4 to 20 mA
<7>
0 V
E (G)
twisted-pair shielded line
control circuit terminal
+
1
<3>
<5><8>
-
<3>
<8>
Ground
Drive
-
+
FM
-
+
AM
Motor
IM
3
49