Absolute Maximum Ratings; Electrical Characteristics - Safran LRF 6019 Manual

Table of Contents

Advertisement

LRF 6019 Integrator Manual
5.4.1

Absolute maximum ratings

These are specifications for stress limits only. Functional operation of the device at these ratings or above
is not implied. Exposure to absolute maximum rating conditions for extended periods of time may affect
reliability and cause permanent damage to the device.
Parameter
PWR_IN *
5V_HI_PWR *
PWR_SAFE
RS232/RS422
RS232/RS422 Interface Select
Operating temperature
Storage temperature
* Reverse polarity protection for negative voltages only, the range of negative voltages is not
operational.

5.5 Electrical characteristics

Typical values -> PWR_IN = 5V; T = 25°C (unless otherwise noted); Laboratory power source.
Max values -> PWR_IN and/or 5V_HI_PWR at 5V over all temperature range.
Parameter
Power consumption OFF state with PWR_SAFE
Power consumption Standby
Power consumption normal operating
Power consumption during a range measurement
Power consumption during pointing, LRF6019-LP
Power consumption during pointing, LRF6019-HP
Inrush current peaks during measurement *1)
Input capacitance on 5V_HI_PWR
Input capacitance on PWR_IN
PWR_SAFE rise time
*1) See Warning on current peaks
914928_TML_LRF6019_en_Version C
Confidential & Proprietary  Safran Vectronix AG – All rights reserved
conditions
Min
5V_HI_PWR = 5V
PWR_IN <= 10 V
PWR_IN > 10 V
Typical
Typical
Typical
Typical
Typical
Typical
Typical
200
Typical
350
Typical
Min
Max
Unit
-15
+15
V
-5.5
+5.5
V
-0.3
5.5
V
-15
15
V
-0.3
5
V
-35
70
°C
-40
85
°C
Typical
Max
40
300
40
300
10
65
150
430
500
2.5
3
0.75
1
1.1
1.4
2
3
350
500
1.5
Public: 04.2019
Page: 33/70
Unit
µW
µW
mW
mW
mW
W
W
W
A
µF
µF
ms