10) Connect the flexcable to the Laserbox (orientate the flexcable towards the laser module)
11) Place the Laserbox in the desired location with the type label facing up.
Warning
 The bending radius of the fiber should not be less than 5 mm.
 Do not kink the fiber.
 Do not pull the fiber connectors.
12) To mount the Laserbox, use the four mounting screws (B) and tighten to 30 Ncm
13) Before commissioning the LRF module, check the fiber and the fiber connections for damage
NOTICE
 ESD protective measures must be observed during the entire assembly process.
 The fiber and flex cable must not be routed over any sharp edges.
 The flex cable must not be folded more than twice in the same place.
 The fiber and the flexcable must be fixed (e.g. with tape) and not able to move to prevent
damage from shock and vibration during use.
 Only those screws mentioned in the instructions may be loosened or removed.
 Operating the LRF with the Laserbox detached results in an offset in measurement results of
about + 0.3 m due to the use of the additional flexcable.
 Only use the flexcable included in the set 914757.
914928_TML_LRF6019_en_Version C
Confidential & Proprietary  Safran Vectronix AG – All rights reserved
Figure 13: LRF 6019 with detached Laserbox
Public: 04.2019