6.5 Absolute maximum ratings

These are specifications for stress limits only. Functional operation of the device at these ratings or above is
not implied. Exposure to absolute maximum rating conditions for extended periods may affect reliability and
cause permanent damage to the device.
Parameter
PWR_IN *
PWR_SAFE
RS232/RS422
RS232/RS422 Interface Select
Operating temperature
Storage temperature
* Reverse polarity protection for negative voltages only, the range of negative voltages is not
operational.

6.6 Electrical characteristics

Typical values -> PWR_IN = 12V; T = 25°C (unless otherwise noted); Laboratory power source.
Max values -> PWR_IN at 12V over all temperature range.
Parameter
Power consumption OFF state with PWR_SAFE
Power consumption Standby
Power consumption normal operating
Power consumption during a range measurement
Power consumption during pointing, LRF6042 LP
Power consumption during pointing, LRF6042 HP
Inrush current peaks during start up
Inrush current peaks during measurement *1)
Input capacitance on PWR_IN
PWR_SAFE rise time
*1) See Warning on current peaks
INTEGRATOR MANUAL LRF 6042 917657- A
Confidential & Proprietary  SAFRAN VECTRONIX AG – All rights reserved
conditions
Typical
Typical
Typical
Typical
Typical
Typical
Typical
Typical
Typical
Min
Max
-43
+43
-0.3
5.5
-15
15
-0.3
5
-35
70
-40
85
Min
Typical
5
100
450
2.5
0.75
1.1
0.65
1500
Public: 02.2022
Page: 24/64
Unit
V
V
V
V
°C
°C
Max
Unit
20
mW
175
mW
500
mW
3
W
1
W
1.5
W
3
A
1
A
uF
1.5
ms