Esd Protection; Operating Conditions - Safran LRF 6019 Manual

Table of Contents

Advertisement

LRF 6019 Integrator Manual

5.3 ESD protection

NOTICE
CAUTION: ESD (Electro-Static Discharge) sensitive device. Permanent damage may occur on
unconnected devices subject to high energy electrostatic fields. Unused devices must be stored
in conductive foam or shunts. Personnel should be properly grounded prior to handling this
device. The protective foam should be discharged to the destination socket before devices are
removed.
Parameter
All Lines

5.4 Operating conditions

Parameter
Operating Voltage PWR_IN
Operating Voltage 5V_HI_PWR
Operating Voltage PWR_SAFE
Typical values are recommended for operation.
There are two options to supply the module. Only one input shall be used:
 PWR_IN
 5V_HI_PWR
914928_TML_LRF6019_en_Version C
Confidential & Proprietary  Safran Vectronix AG – All rights reserved
Typical
Note
+2kV
Human body model (HBM)
+1kV
Charged-device model (CDM)
Figure 23: Possible supply connections
Min
Typical
Max
3.3
5.0
15
4.75
5.0
5.25
3
5.0
5.25
Public: 04.2019
Page: 32/70
Unit
V
V
V